Search results for " sonography"
showing 10 items of 40 documents
Diagnostic accuracy of current sonographic criteria for the detection of outflow abnormalities in the internal jugular veins
2012
Objectives: This study was aimed at evaluation of the diagnostic value of Doppler sonography for the assessment of abnormalities in the internal jugular veins (IJVs). Method: One hundred and sixteen IJVs were assessed in 58 patients with associated multiple sclerosis. Findings of Doppler sonography were compared with results of the reference test: catheter venography. Results: At least one positive extracranial sonographic criterion suggesting venous abnormality was found in 92.2% of the assessed veins. Yet, sensitivity, specificity, positive and negative predictive values of sonography were low: 93.4%, 12.0%, 79.4% and 33.3% for at least one positive criterion, and for at least two positiv…
Management of Pneumothoraces Detected on Chest Computed Tomography: Can Anatomical Location Identify Patients Who Can Be Managed Expectantly?
2014
Abstract Background Pneumothorax (PTX) can be readily detected by computed tomography (CT) or ultrasound. However, management of PTX in hemodynamically stable patients remains controversial. Study Objectives We sought to investigate whether a distinct anatomical distribution of PTX along prespecified chest zones as detected by CT can be described in patients with or without subsequent chest tube thoracotomy (CTT), thus potentially allowing the extended focused assessment with sonography for trauma (EFAST) ultrasound examination to guide PTX management. Methods We performed a retrospective review of chest CT scans performed in the emergency department (ED) of a Level I trauma center. CT scan…
Umbilical cord cysts: evaluation with different 3-dimensional sonographic modes.
2010
Objective. The purpose of this series was to determine whether the use of different 3-dimensional (3D) sonographic modes allows better definition of umbilical cord cysts and pseudocysts in utero. Methods. Two cases of umbilical cord cysts and 1 of a pseudocyst were analyzed and compared with 2-dimensional (2D), 3D, angiopower Doppler, tomographic ultrasound imaging (TUI), virtual organ computer-aided analysis (VOCAL), and automatic volume calculation (AVC) sonographic modes. All cases were followed during pregnancy. A karyotype analysis was also obtained. Results. Three-dimensional sonography, TUI, and VOCAL allowed clear visualization and evaluation of the sizes, locations, and numbers of …
Diagnosis of Tinnitus: Neurological Examination
2011
1. There is an urgent need for a set of assessment methods to be agreed upon and utilized by the international tinnitus research community. 2. Neurological examination of tinnitus patients is essential to achieve a good diagnostic approach to the different forms of objective and subjective tinnitus. 3. This chapter summarizes the neurological examination in tinnitus, including the protocol used in the authors’ tinnitus clinic, which is based on the consensus of the Tinnitus Research Initiative (TRI).
Control of intrauterine device insertion with three-dimensional ultrasound: is it the future?
1996
A comparative study was designed to determine whether three-dimensional transvaginal sonography (3D-TVS) offered advantages over two-dimensional transvaginal sonography (2D-TVS) for the identification and location of IUDs in 66 asymptomatic women. Hysteroscopy was performed in cases in which there was a discrepancy between the information obtained by both methods (n = 14). In eight cases (12.2%) the IUD was misidentified with 2D-TVS. In six cases (9.1%) it was not possible to identify the device model with 2D-TVS. In two cases (3.0%) 2D-TVS failed to identify the position of the device. In contrast, all IUDs were identified and located accurately with 3D-TVS. © 1996 John Wiley & Sons, Inc.
Riscontro incidentale di noduli tiroidei: incidenza, aspetti B-mode e color Doppler in una popolazione adulta studiata con "real-time compound sonogr…
2006
Riscontro incidentale di noduli tiroidei: incidenza, aspetti B-mode e color Doppler in una popolazione adulta studiata con “real-time compound sonogr…
2006
Localization of segmental arteries in renal surgery by Doppler sonography.
1982
Abstract To avoid damage to major arteries of the renal parenchyma during nephrotomy, intraoperative Doppler sonography was used experimentally and clinically as an artery finder. In experiments with 7 beagles segmental arteries were detected easily and reliably by sonography, and the arterial course thus indicated correlated perfectly with arteriograms and casts. In a clinical trial the Doppler artery finder was used in 7 patients with staghorn calculi that were removed via the renal pelvis and additional multiple selective nephrotomies. With as many as 7 selective nephrotomies in a single kidney there was no damage to the major arteries in any of these patients. Selective, avascular nephr…
Duplexsonographie der normalen Pfortader
2008
In 50 normal subjects flow velocity and direction on the portal vein was measured by ultrasonic duplex system. The measurements revealed at a mean diameter of 9.7 mm, a mean flow velocity of 15.2 +/- 2.6 cm/s, corresponding to a volume flow of 693 +/- 235 ml/min. Postprandially this increased to 880 +/- 269 ml/min. Inter-observer and day to day measurements demonstrated good reproducibility. Thus, this simple non-invasive method is well suited for quantitative assessment of the portal vein system in portal hypertension, thrombosis or after shunt operations.
Role of high-resolution ultrasonography without and with real-time spatial compound imaging in evaluating the injured posterior cruciate ligament: pr…
2009
This study sought to compare high-resolution ultrasonography (HRUS) without and with compound imaging in evaluating the injured posterior cruciate ligament (PCL). Thirteen patients with a magnetic resonance imaging (MRI) diagnosis of PCL lesions (ten acute and three chronic) and 20 healthy controls underwent conventional and compound HRUS performed by the same radiologist who was blinded to the subjects' case-control status. The PCL was scanned in a longitudinal direction in all cases. HRUS images were assessed for PCL thickness by two other radiologists blinded to the number and type of PCL injury. PCLs were classified as normal or injured, and the latter as having acute or chronic injurie…